If the shading is controlled by a solar-heat model and you have Pendax CONDUCTOR, data is collected continuously and can be exported as a traceable basis for your energy and sustainability reporting. One of Pendax SOLO's clearest advantages.
What kind of data is it?
The shade itself doesn't measure electricity. What CONDUCTOR does is calculate what the shading actually contributed, hour by hour:
- Estimated blocked solar heat – how much solar energy the fabric kept out of the room.
- Estimated avoided cooling energy – how much cooling therefore didn't need to be produced.
- Indicative climate impact – an estimated emissions figure, based on a location-based factor.
The calculation builds on the solar irradiance at the façade, the shade's actual position over time, the glass area, the temperature and established assumptions about the shade's effect and the cooling system's efficiency.
A model-based estimate
The result is a model-based estimate, and that is in fact exactly what makes the basis useful for ESG.
Instead of a number with no origin, the method, the assumptions and the data coverage are shown openly. You can demonstrate how a value was produced – right down to the inputs and the uncertainty. That makes it a credible decision and ESG basis that stands up to external review, rather than a claim that can't be substantiated.
What needs to be in place
A few things are required in the installation for usable energy figures:
- The right decision model. One of the solar-heat models – internal or external shading – is what generates the energy basis. Other models control well, but don't report energy.
- A light sensor. Measures the real solar irradiance at the façade – the basis for the calculation.
- Outdoor temperature. Today via the weather API for the location's coordinate.
- Glass area and façade data. Measured dimensions give the highest precision; if they're missing, the area is estimated so you still get figures from the start.
- Pendax CONDUCTOR. Collects, stores history and exports.
- Sufficient data coverage across the reporting period.
You can see which solar-heat model and which accessories suit your particular building in the configuration tool.
How the data comes out
CONDUCTOR aggregates the readings per interval – irradiance, position, temperature and blocked solar energy – and builds up a history. From there you can follow the trend over time and export the basis to your reporting. (If you want to understand how the unit knows where the sun is and why it acts as it does, read How does the decision engine work?)
Before you report externally
Describe the result as an estimate, and verify the inputs, assumptions and data coverage before the figures are used in an external report. Then the shading's climate contribution is both honest and defensible – and you have something concrete to bring to the board, the tenant or the auditor.